NPort 5100 Series Web Console Configuration
5-4
Web/Telnet Console
The “Disable” option for “Web Console” and “Telnet Console” is included for security reasons. In some cases,
you may want to disable one or both of these console utilities as an extra precaution to prevent unauthorized
users from accessing your NPort 5100. The factory default for both Web console and Telnet console is Enable.
Web console
Setting Factory Default Necessity
Enable or Disable Enable Required
Telnet console
Setting Factory Default Necessity
Enable or Disable Enable Required
ls.
Reset button protect
Setting Factory Default Necessity
No or Yes None Optional
NOTE: Select the Yes option to allow limited use of the Reset Button. In this case, the Reset Button can be used
for only 60 seconds. I.e., 60 sec. after booting up, the Reset Button will be disabled automatically.
Network Settings
You must assign a valid IP address to the NPort 5100 before it will work in your network environment. Your
network system administrator should provide you with an IP address and related settings for your network. The
IP address must be unique within the network (otherwise, the NPort 5100 will not have a valid connection to the
network). First time users can refer to Chapter 3, Initial IP Address Configuration, for more information.
You can choose from four possible IP Configuration modesStatic, DHCP, DHCP/BOOTP, and BOOTP
located under the web console screens IP configuration drop-down box.