VPort 254 User’s Manual System Configuration
4-40
TCP Client Mode (only available in Serial Device Control and TCP Client Mode)
Setting Description Default
Destination IP address
Allows the VPort to connect actively to
the remote host whose address is set by
this parameter.
blank
Designated Local port
TCP port number for the connection. It
can also be enabled or disabled.
disable
TCP Connect On
Startup: A TCP connection will be
established on startup, and will remain
active indefinitely.
Any Character: A TCP connection will
be established when any character is
received from the serial interface, and
will remain active indefinitely.
Startup
NOTE
To avoid influencing the video performance, it is strongly recommended that the VPort’s COM
port should be used for simple serial control and data transmission, such as a card reader.
Parameters
Some COM port parameters need to be configured.
Port Settings
Setting Description Default
Baud rate (bps)
The baud rate specified by the PTZ
camera’s serial communication specs.
2400
Data bits 8
Stop bits 1
Parity bits
The parameters used to define the serial
communication.
None