VPort 254 User’s Manual Getting Started
2-17
Grounding the VPort 254
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the ground screw to the grounding surface prior to
connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded mounting surface such as a metal
panel.
Wiring the Redundant Power Inputs
The VPort 254 has two sets of power input, power input 1 and power input 2, which are located on
the 6-pin and 8-pin terminal block connectors. Top and front views of the terminal block
connectors are shown here.
PWR1 PWR2
PWR1
PWR2
V1- V1+ V2- V2+
V1- V1+ V2- V2+
STEP 1: Insert the negative/positive DC or
AC wires into the V-/V+ terminals.
STEP 2: To keep the DC or AC wires from
pulling loose, use a small flat-blade
screwdriver to tighten the wire-clamp screws
on the front of the terminal block connector.
STEP 3: Insert the plastic terminal block
connector prongs into the terminal block
receptor, which is located on the VPort
351’s top panel.
ATTENTION
The power for this product is intended to be supplied by a Listed Power Unit, with output marked
LPS, and rated to deliver 12 to 32 VDC at a maximum of 740 mA, or 18 to 30 VAC at a maximum
of 890 mA.
ATTENTION
Before connecting the VPort to the AC/DC power inputs, make sure the DC power source voltage
is stable.