DA-681 Series Hardware User’s Manual Hardware Installation
Power Input Wiring Description
Read the following section for a detailed power input wiring description.
1
2
3
4
5
6
7
8
9
10
1 3 5 7 92
4 6 8 10
PWR1 PWR2
+/L /N
+/L /N
NC
Terminal Number Description Note
1 PWR1 Line / DC +
PWR1 Line / DC + is connected to the
positive (+) terminal if the power source is
DC, or to the Line terminal if the power
source is AC.
2 PWR1 Neutral / DC –
PWR1 Neutral / DC – is connected to the
negative (–) terminal if the power source is
DC, or to the Neutral terminal if the power
source is AC.
3 PWR1 Surge Ground
PWR1 Surge Ground is connected to the
Chassis Ground via a jumper on the
terminal block. Surge Ground is used as
the ground conductor for all surge and
transient suppression circuitry. NOTE:
Surge Ground must be disconnected from
Chassis Ground during HIPOT (dielectric
strength) testing.
4 Chassis Ground
Chassis Ground is connected to the Safety
Ground terminal for AC inputs, or the
equipment ground bus for DC inputs.
Chassis ground connects to both power
supply surge grounds via a removable
jumper.
5 NC
No function
6 NC
No function
7 Chassis Ground
Chassis Ground is connected to the Safety
Ground terminal for AC inputs or the
equipment ground bus for DC inputs.
Chassis ground connects to both power
2-9