Moxa ONCELL G2110-T Manual de usuario Pagina 69

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 105
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 68
OnCell G2100 Series User’s Manual AT Command Set
4-11
3. Type AT&W and press Enter to save the settings.
Modifying Data Bits and Parity
1. Type AT+ICF=x,y and press Enter, where x and y correspond to the following parameters.
1 8 data bits, 2 stop bits
2 8 data bits, 1 parity, 1 stop bit
3 8 data bits, 1 stop (default)
4 7 data bits, 2 stop bits
5 7 data bits, 1 parity, 1 stop bit
x = Data bits/ stop bits
6 7 data bits, 1 stop bit
0 Odd parity
1 Even parity
2 Mark parity
3 Space parity
y = Parity
4 None parity (default)
For example, type AT+ICF=5,1 to change the parameters from 8n1 to e71:
Vista de pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 104 105

Comentarios a estos manuales

Sin comentarios