- 8 -
This product is intended to be mounted to a well
-grounded
mounting surface, such as a metal panel.
Wiring the Redundant Power Inputs
The 4-contact terminal block connector on the AWK-1121’s top panel is
used for the AWK-1121’s two DC inputs. The top and front views of the
terminal block connector are shown here.
Top View
Front View
Insert the negative/positive DC wires
V-/V+ terminals.
To keep the DC wires from pulling
-
blade screwdriver to tighten the
wire
-clamp screws on the front of the terminal
Insert the plastic terminal block
connector prongs into the terminal block
receptor, which is
located on the AWK-1121’s t
AWK-1121
to the DC power inputs, make
sure the DC power source voltage is stable.