ICF-1150 Series Quick Installation Guide First Edition, November 2008 © 2008 Moxa Inc. All rights reserved. Reproduction wit
- 2 -Overview Introduction The ICF-1150 series fiber converters are equipped with a multiple interface circuit that can handle RS-232 and RS-422/485
- 3 -Rotary Switch for Pull High/Low Resistor Setting Since the RS-485 port can support multi-drop connection or daisy-chain connection, system engi
- 4 -Features y “Ring” or “Point to Point” transmission y Extend RS-232/422/485 transmission distance: ¾ up to 40 km with single-mode—ICF-1150-S
- 5 -ICF-1150-ST 13.66708.88.848.3933.4111530.3 Top View Front View LEDFiber PortOP Mode SwitchRotary Switch for Pull High/Low ResistorRS-422/485
- 6 -Mounting The aluminum DIN-Rail attachment plate should be fixed to the back panel of the ICF-1150 when you take it out of the box. If you need
- 7 -Fiber Cable SC-Port Pinouts SC-Port to SC-Port Cable Wiring TxRx AABBCable WiringA AB
- 8 -ATTENTION For Fiber Ring Users: If the Rx LEDs of the converter glow continuously, remove the fiber cable and connect again, then the system w
- 9 -ICF-1150I- S/M-SC/ST: 163 mA @ 12V Mechanical Dimensions (W × D × H) 30.3 × 70 × 115 mm Material Aluminum (1 mm) Gross Weight 135g Reg